  • Reliably handle a wide range of high-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC

  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors

  • CAT IV 600 V, CAT III 1000 V rating for added user protection

  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability

  • High voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool

  • Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter

  • Accurately measure frequency up to 1 kHz for optimum troubleshooting

  • Quickly analyze readings using the MIN, MAX, and AVG functions

  • A large backlit display allows for easy visibility in low-lit areas

  • Use the display hold feature to capture readings even when the display cannot be viewed

  • Use the low-pass filter to smooth out noisy loads and stabilize readings

Product Specification

Brand

Fluke

Product Type

Clamp Meter

Product Model

355

Electrical Specifications

Current Measurement DC and AC 10 Hz to 100 Hz

Range

40 A / 400 A / 2000 A / 1400 AC rms

Resolution

10 mA / 100 mA / 1 A

Accuracy

A: 1.5% rdg + 15 digits
A: 1.5% rdg + 5 digits

Trigger Level For Inrush

0.50 A / 5.0 A / 5 A

Trigger Level for Hz Filter OFF

2.50 A / 2.5 A / 8 A

Trigger Level for Hz Filter ON

0.50 A / 2.5 A / 8 A

Crest Factor (50/60 Hz)

Range

40 A / 400 A / 2000 A / 1400 AC rms

Crest Factor1

2 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A

Current Measurement AC 100.1 Hz to 1 kHz

Range

40 A / 400 A / 2000 A; 1400 AC rms

Resolution

10 mA / 100 mA / 1 A

Accuracy

10 A: 3.5% rdg + 15 digits
10 A: 3.5% rdg + 5 digits

Trigger Level for Inrush

0.50 A / 5.0 A / 5 A

Trigger Level for Hz Filter OFF

2.50 A / 2.5 A / 8 A

Trigger Level For Hz Filter ON

0.50 A / 2.5 A / 8 A

Voltage measurement DC and AC 10 Hz to 100 Hz
(600 V and 1000 V Ranges Have 10% Over Range to 660 V and 1100 V Respectively)

Range

4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC

Resolution

1 mV / 10 mV / 100 mV / 1 V

Accuracy

1% rdg + 10 digits
1% rdg + 5 digits

Trigger Level for Hz Filter OFF

0.25 V / 6 V

Trigger Level For Hz Filter ON

0.25 V / 6 V

Voltage Measurement AC 100.1 Hz to 1 kHz
(600 V and 1000 V Ranges Have 10% Over Range to 660 V and 1100 V Respectively)

Range

4 V / 40 V / 400 V / 600 V ac rms

Resolution

1 mV / 10 mV / 100 mV / 1 V

Accuracy

3% rdg + 10 digits
3% rdg + 5 digits

Trigger Level for Hz Filter OFF

0.050 V / 0.25 V / 6 V

Trigger Level For Hz Filter ON

0.050 V / 0.25 V / 6 V

Ohms Measurement

Range

4 kΩ / 40 kΩ / 400 kΩ

Resolution

0.1 Ω / 1 Ω / 10 Ω / 100 Ω

Accuracy

1.5% + 5 digits

Continuity Beeper

On at ≤ 30 Ω
Off at ≥ 100 Ω

Frequency Measurement

Measurement Range

5.0 Hz to 1 kHz

Resolution

0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)

Accuracy – 5.0 Hz to 100 Hz

0.2% + 2 counts

Accuracy – 100.1 Hz to 1 kHz

0.5% + 5 counts

Trigger Level

Refer To Current And Voltage Tables

1. Add 2% to error spec for CF > 2

General Specifications

Batteries

Six 1.5 V AA NEDA 15 A or IEC LR6

Battery Life (with Typical Usage, Backlight Off)

100 Hours

Test Leads

Rated to 1000 V

Jaw Size

58 mm (2.28 in)

Environmental Specifications

Operating Temperature

32°F to +122°F (0°C to +50°C)

Storage Temperature

-4°F to 140°F (-20°C to +60°C)

Operating Humidity

0 to 95% (non-condensing)

Operating Altitude

2000 m

Storage Altitude

10,000 m

IP Rating

42 (indoor use only)

Drop Test Requirements

1 m

Temperature Coefficients

Current

0.1% of reading per °C outside 22°C to 24°C

Voltage

0.1% of reading per °C outside 22°C to 24°C

Safety Rating

IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

Dimensions (L x W x D)

300 x 98 x 52 mm (12 x 3.75 x 2 in)

Weight

.814 kg (1.8 lb)


Other Details

Dimension (CM) - L x B x H

Unit of Measurement

Weight

kg

Generic Type

Clamp Meters

Manufacturer Details

Fluke, Fluke Technologies Pvt Ltd, Art Guild House, Kurla West Mumbai-400070

Packer Details

Fluke, Fluke Technologies Pvt Ltd, Art Guild House, Kurla West Mumbai-400070

Country of Origin

India

Write a review



Your review has been posted...!

Purchase this product to review...!

Give your valuable Rating, Review Title & Comments...!

Holding down the CTRL key as you click a image, allows you to select more than one. Upload valid image file(s)..!

Purchase this product to review...!
Thank you for your valuable feedback..!
Sending..!
Average user rating

Rating/ 5

Overall Rating
5
80% Complete (danger)
4
3
2
1

Close X