The DT4281 is our top-of-the-line high-precision 60000 count digital multimeter with all of the functions and features required for advanced testing in complex power and electrical applications
-
±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics
-
Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
-
Measures large currents with optional clamp probe (only for DT4281, which has no 10 A terminal for accident prevention)
-
Terminal shutter mechanism (prevents erroneous test lead insertion)
-
Dual display lets you check voltage and frequency simultaneously
-
The Ultimate Digital Multimeter, Featuring A Design Focused On Safety That’s Critical For Electrical Work
-
The DT4281, which is part of Hioki’s DT4280 series of high-end digital multimeters, is designed for maximum safety in electrical work
-
Connect an AC clamp to safely measure current
-
Accurately Measure The Voltage Output From The Secondary Sides Of Inverters By Eliminating Harmonic Components
-
Measure the fundamental wave alone by eliminating harmonic components with the DT4281’s low-pass filter function
-
Measure The Ripple Voltage Of DC Charging Systems
-
Measure ripple voltage with a superposed DC signal by using peak value measurement and DC + AC voltage measurement
-
Percentage Display For 4 To 20 mA Instrumentation Signals
-
The digital multimeter can convert and display instrumentation signals of 4 to 20 mA or 0 to 20 mA representing properties such as temperature, pressure, and flow rate from a transducer or other device that converts sensor data into an electrical signal
-
600.00 μA Range For Measuring Very Low Currents Used By Gas-Burning Devices
-
Accurately measure the very low currents such as burner flame currents
-
Clamp-On Sensor Based Current Measurement Eliminates The Cause Of Accidents
-
Mistakenly measuring voltage using the current range may lead to a short-circuit
-
The DT4281 eliminates the root cause of such accidents by providing clamp-on sensor based current measurement functionality instead of using conventional probes
-
True RMS Measurement For Accurate Measurement Of Even Distorted Current Waveforms
-
Digital multimeters implement two types of measurement: mean-value measurement and true RMS measurement
-
The two methods yield significantly different measurement results for current waveforms, which are often distorted
-
For accurate measurement, it is necessary to use an instrument with true RMS capability
-
Measurement Data Can Be Downloaded To, Reviewed On, And Saved To A Computer
-
Connect the DT4281 to a PC with the optional Communication Package DT4900-01 to easily graph data stored in the DMM’s internal memory and display measurement results in real time on the computer
-
Save important measured values in text format
-
Safe Measurement Requires Use Of An Instrument That Suits The Measurement Location
-
To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV)
-
Using an instrument that does not satisfy the required safety level can lead to an electrical accident
ProductSpecification
Brand | Hioki |
Product Type | Digital Multimeter |
Product Model | DT4281 |
DC Voltage Range | 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt |
AC Voltage Range | 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz |
DC + AC Voltage Range | 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz |
Resistance Range | 60.000 Ω to 600.0 MΩ, 8 ranges, Basic accuracy: ±0.03 % rdg. ±2 dgt |
DC Current Range | 600.00 μA to 600.00 mA, 4 ranges |
AC Current Range | 600.00 μA to 600.00 mA, 4 ranges (True RMS, crest factor 3) |
AC Current Range (Use With Clamp On Probes) | 10.00 A to 1000 A, 7 ranges |
Peak | DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated) |
Capacitance Range | 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt |
Continuity Check | Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more |
Diode Test | Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages |
Frequency Range | AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio) |
dB Conversion | Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages |
Temperature (Thermocouples) | K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) |
Other Functions | Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion |
Display | Main and sub displays: 5-digits LCD, max. 60000 digits |
Display Refresh Rates | 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) |
Power Supply | LR6 (AA) alkaline batteries × 4, Continuous use: 100 hours |
Included Accessories | Test Lead L9207-10 × 1, Instruction Manual × 1, LR6 Alkaline Battery × 4 |
Dimensions (W x H x D) | 93 x 197 x 53 mm 3.66 x 7.76 x 2.09 Inch |
Weight | 650 g / 22.9oz |
Warranty | As Per Manufacturer Terms and Condition |
OtherDetails
Dimension (CM) L x B x H | 24.5 x 13.3 x 6.9 |
Unit Of Measurement | 1 Piece |
Weight | 0.680 kg |
Generic Name | Digital Multimeter |
Packer Details | Hioki Unit No. 123 & 124, 1st Floor, Suncity Business Tower, Golf Course Road, Gurugram - 122003, Haryana, India Phone : 08035948127 |
Importer Details | Hioki Unit No. 123 & 124, 1st Floor, Suncity Business Tower, Golf Course Road, Gurugram - 122003, Haryana, India Phone : 08035948127 |
Country Of Origin | India |